Home Suppliers Feedback Search      GENTAUR HEADQUARTERS  +32 1641 4407  +32 1650 9045 

                                                                                                                                              mail: [email protected]


Europe

 

GENTAUR France SARL

Rue Lagrange, 9

75005 Paris, France

 01 43 25 01 50

 

GENTAUR Germany

IME, Frockenbeckstrasse 6

52074 Aachen, Germany

 +32 1658 9045

 

GENTAUR Italy

23015 Milano, Italy

 02 36 00 65 93

 

Česká republika Praha
+420246019719

 

Denmark

+4569918806

 

Finland Helsset
+358942419041

 

Ελλάς Αθήνα
+302111768494

 

Ireland Dublin
+35316526556

 

Luxembourg
+35220880274

 

Magyarország Budapest
+3619980547

 

Nederland
+31208080893

 

Norge Oslo
+4721031366

 

Österreich
+43720880899

 

Sverige Stockholm
+46852503438

 

Schweiz Zürich
+41435006251

 

 

Northern America

 

Canada Montreal
+15149077481

 

US New York
+17185132983

 

 

Asia

 

日本
 +81 78 386 0860

Other Countries
0032 (0)16 41 44 07

 

 

Clonagen

Gentaur

Genprice

Bioxys

Labprice




Rat TSH ELISA - For Research Use Only

 

 

 

Key points for ELISA
																	Dilution of condensed reagents - standard solution, Labeled antibody solution
																	Washing of microplate - Dilution of washing buffer, High bank absorbance, Low or too much colouration, Peeling off of capture antibody
																	Shaking of microplate - Low colouration, Big variation, Poor sensitivity, 600 ~ 1,200rpm, 10sec.x3 times
																	Assay circumstance - Room temp(20~25 Celsius), Humidity(>30%), Airflow(0,4m/sec.>), Level, Avoidance of direct sunlight
																	Precaution to the safety - Gloves, Glasses, Mask, Laboratory Coats, 1M Sulphuric Acid, Assay Sample handling, Disposal of materials after assays, Storage of kits and term of validity
																	Instrumentation - Beaker-Graduated cylinder, Pipette - Tips, Vortex-type mixer, Thermometer-Hygrometer, Timer, Microplate reader(450nm, 620nm), Test tubes, Test rucks, others
																	Temperature adaptation - Temperature Adaptation Time, For partial use, TMB
																	Handling of pipette - Touch&Go, Pre-wetting, Co-washing

 

We would like to inform you that the highly sensitive Rat Thyroid Stimulating Hormone ELISA Kits from Shibayagi is available again and is quickly taking over the biological sphere.


These assays were unfortunately discontinued in 2012, but now Shibayagi released the new and improved version of those assays.


It is the most sensitive Rat TSH ELISA on the market. It uses 2 2 monoclonal antibodies directed to the α- and β-subunits of the TSH molecule which is a heterodimer.



Reference values:

Male CD (SD) rats, 9 weeks of age, fasting, TSH values: 3,26~4,65 ng/ml , n=5


Male CD (SD) rats, 7 months of age, non-fasting, TSH values: 2,50~4,04 ng/ml, n=5


Male CD (SD) rats, 9 weeks of age, non-fasting, thyroidectomized, TSH values: 8,09~11,9 ng/ml , n=5



 